Sterilization Monitoring Products

STERINTECH Labeling Solutions

Proper documentation and the possibility to trace packed instrument trays and containers is essential in case of recalls . This also serves for Patient Record purposes.

STERINTECH offers 2 and 3 line Labels

which can be used for the above purpose with a variety of Labeler Guns.

There are 3 types of Labeler Guns available with us

The labels are available for STEAM, Ethylene Oxide and PLASMA – H202
sterilization for each labeler gun.

Ordering Information :

AVAILABLE VARIANTS
Monarch Labeller (603.003.0001) Steam Monarch (605.111.9000) EO  Monarch (605.031.9000) Plasma Monarch (605.021.9000)
Blitz Labeller (601.001.0001) Steam Blitz (606.010.7500) EO Blitz (606.030.7500) Plasma Blitz (606.020.7500)
Blitz Labeller (601.001.0001) Steam Sterieco (606.010.4000) EO  Sterieco (606.030.4000)   NA
Blitz Labeller
(444)
Steam Small (605.511.9000) EO Small (605.530.9000) NA
2 Liner Labeller
(602.002.0001)
Steam 2 Liner
(602.011.9000)
EO 2 Liner
(602.031.9000)
Plasma 2 Liner
(602.021.9000)

Sterintech Process Indicator Tapes

The Sterintech Process Indicator Tapes are used to tape the packaging materials of wrapped instrument trays. Next to a good stickiness, the tapes, also provide in a ISO 11140 – 1 complaint indicator to distinct processed and unprocessed instrument trays.

Autoclave Tapes

The Sterintech White Steam tapes are used to tape the packaging materials of wrapped instrument trays. Next to a good stickiness the White Steam tapes also provide a ISO 11140 – 1Type 1 steam indicator to distinguish processed and unprocessed instrument trays. The tape materials are produced in accordance with our ISO 13485 based procedures. All working instructions and checking methods are laid-down in our Quality Assurance system which is audited twice a year internally and once year by external auditors.

EO Tapes

The Sterintech EO tapes are used to tape the packaging materials of wrapped instrument trays which are sent for EO sterilization. All chemical indicator inks used for the production are water­ based, environmental friendly inks. Chemical indicators do not contain any heavy metals nor toxic substances .The tape material glue is not containing Natural Rubber Latex.

Plasma Tapes

The SterintechTM Plasma tapes are used to tape the packaging materials of wrapped instrument trays to be sterilized in a plasma cycle. The colour change of the tape is from Red to Yellow.

Sterintech Bowie-Dick Test Systems

The Bowie Dick Test Pack has been a standard test for Hospital Steam Sterilizers since 1963.

At the beginning of every working day the Bowie Dick Test Pack needs to be used to test the performance of each (pre-vacuum) steam sterilizer. At a successful completion of the Bowie Dick Test Cycle the Steam sterilizer can be released for usage during the day.

Sterintech Batch Control Solutions

The STERINTECH BATCH CONTROL HELIX TEST (or BCHT in short) is a test which is recommended by the Dutch RIVM, German Robert Koch Institute and specified in the EN 285 Amendment A;2009 as a Sterilization performance test.

Standard description of a Process Challenging Device consists of a Chemical Indicator Holder connected to a 1.5 mtr long tube. When used in every cycle the BCHT is helpful in detecting early failures during the sterilization cycles.

Failure which are picked-up by the BCHT are:

The STERINTECH BCHT's are classified as

Sterintech Inpack Indicators

The sole reason to use in-pack indicators is to detect sterilization conditions inside packs, trays or containers. It serves as a proof of sterilization inside the packs and containers. STERINTECH In-pack indicators are ISO 11140 compliant and tested by an independent micro-biological laboratory. We provide In-pack indicators for Steam, Ethylene-Oxide and Plasma sterilization

After opening the pack in the operating room, the color of the indicators can be evaluated . The Indicators can be stored as evidence on the patient file.

AVAILABLE VARIANTS
Type 6 Emulator 121 C -15 min
134 C - 3.5 min
Pink to Green Box of 500 Strips
Type 6 Emulator 121 C - 20 min
134 C -7 min
Blue to Black Box of 200 Strips
Type 6 Emulator 121 C -12 min
134 C - 4 min
Blue to Pink Box of 200 Strips
Type 6 Emulator 121 C - 20 min
134 C -7 min
Pink to Green Box of 200 Strips
Type 6 Emulator 121 C - 20 min
134 C - 4 min
Blue to Black Box of 200 Strips

Sterintech Inpack Indicators

The sole reason to use in-pack indicators is to detect sterilization conditions inside packs, trays or containers. It serves as a proof of sterilization inside the packs and containers. STERINTECH In-pack indicators are ISO 11140 compliant and tested by an independent micro-biological laboratory. We provide In-pack indicators for Steam, Ethylene-Oxide and Plasma sterilization.

After opening the pack in the operating room, the color of the indicators can be evaluated . The Indicators can be stored as evidence on the patient file.

STEAM

  Type 5 Chemical Indicator 121 C -15 min
134 C - 3.5 min
  Box of  500 Strips
Type 4 Chemical Indicator 121 C -15 min
134 C - 3.5 min
Box of 500 Strips

EO

  Type 5 Indicator 600 mg/l EO concentration at 54°C - 60% RH   Box of 500 strips
Type 4 Chemical Indicator 600 mg/l EO concentration at 54°C - 60% RH   Box of 500 strips

PLASMA

  Type 4 Chemical Indicator 600 mg/ 1 EO Concentration
at 54° C - 60% RH
Box of 200 strips

Sterintech Biological Indicators

The STERINTECH Self Contained Biological Indicators are designed to comply with the ISO 11138 standard . Basically it is a bacillus inoculated strip or metal carrier which is packed together with ampoule inside the plastic vial and closed / sealed with a lid in which a small filter is placed.

The STERINTECH SCBl’s are characterized by the following:

STERINTECH also offers a Digital Incubator for the incubation of the vials. It has self programmed modules for incubation of STEAM , EO and PLASMA Biological Indicators

Sterintech Rapid Biological Indicators

Sterintechth1 Scbi-1 Hour for Steam & Plasma, 4 Hour For EO

The SterintechTM Quick Read-out Biological Indicators (SCBI) are intended to monitor the sterilization condition at specific places inside the load of a sterilizer. SP Medikal is recommending the use of a BI Helix device in combination with the SCBI in order to ensure that air removal and steam penetration is taking into the equation.

Characteristics:

Biological Indicators conform to ISO 11138

Spores: Geobacillus Stearothermophilus ATCC 7953 1x10E6 spores per vial

Color change: Violet to yellow (growth media)

Quick Readout Incubator (220V) for 59°C / 1 hrs

SterintechTM Quick Read-Out Incubator

Intended use of the SterintechTM Quick Read-out Incubator is to incubate and read-out the SterintechTM Quick Read-out Self-Contained Biological indicators. The QR incubator is giving a read-out as from 3-5 minutes after the start of the incubation period. Once the QR Incubator is having a positive fluoresence reading the QR Incubator is printing out a report of the finding. Other brands of Self-Contained Biological Indicators may be used with this incubator after consultancy with SP Medikal.

Advantages

Cleaning Chemistries

Detromatic Enzym

Enzymatic cleaner for medical instruments & Endoscopes

Detro Multicare

Solution for instrument care

Detro Enzym Foam Ready to Use Product

foam product in ready- to- use spray from. Does not contain aldehyde, phenol and chlorine compounds. Thanks to the foam produced by ergonomic spray head the solution covers the instrument homogenously. Thanks to its Foam form, which remains stable for a long time and disperses on the surface in a way that does not allow air contact, it keeps instruments, moist for a long time (during connection and transfer) and at a level that prevents the drying of the organic

Detro Lube Spray

Oiling spray for surgical instruments and air exhausters

Detro Enzym Foam Ready to Use Product

foam product in ready- to- use spray from. Does not contain aldehyde, phenol and chlorine compounds. Thanks to the foam produced by ergonomic spray head the solution covers the instrument homogenously. Thanks to its Foam form, which remains stable for a long time and disperses on the surface in a way that does not allow air contact, it keeps instruments, moist for a long time (during connection and transfer) and at a level that prevents the drying of the organic

Detro Lube Spray